Suppressing Abnormal Discharges in Plasma Processes
Laura Peters, Senior Editor -- Semiconductor International, 11/1/2005
All plasma processes share a common problem that affects yield. Abnormal electric discharges can create particulate matter and cause physical and/or electrical damage to the wafer. Such discharges can also cause the resulting plasma to be unstable.
A group of researchers determined that they could
effectively detect and suppress anomalous discharges in plasma equipment using
the signals from two probes that can predict the occurrence of abnormal
discharges. The discharges are then suppressed by controlling the voltage
applied to the electrostatic chuck in a reactive ion etch (RIE) system.
Reporting on their findings at the recent IEEE
International Symposium on Semiconductor Manufacturing
(ISSM 2005) were M. Yasaka (currently at the Ariake National College of
Technology in Fukuoka, Japan) and colleagues with the Tokyo Cathode Lab
(Kumamoto, Japan), NEC
Electronics, the Kumamoto
Industrial Research Institute and the Kyushu Institute of
Technology .
The researchers used two sensors: an acoustic emission (AE) sensor and a view-port (VP) probe. The VP probe was specifically designed for this application and is able to detect changes in plasma potential just prior to anomalous electrical discharge. The AE sensor detects the acoustic waves emitted from the point where the discharge occurred. The detection of a supersonic wave signal is independent of plasma generation method (DC or RF).
The VP probe uses a transparent electrode film made of indium tin oxide, which is positioned between the inner, thin quartz glass and the outer, thick glass of the RIE system's view port. The VP probe detects a difference in charge buildup at the inner glass surface of the viewing port. The AE detectors are able to monitor the occurrence of abnormal discharge, and can also be used to identify the location of the discharge by analyzing the acoustic signals detected by multiple AE detectors attached at different locations inside the process tool. The AE sensor was attached to the top surface of the RIE tool with three AE sensors located around the periphery of the chamber. The study also used an in situ particle monitoring system capable of detecting titanium particles >70 nm in diameter.
The parallel-plate RIE system used 13.56 MHz excitation voltage, and anomalous discharges were induced using moisture on a titanium-coated wafer mounted on the RF electrode by an electrostatic chuck (ESC) with helium backside cooling. RF power of 1000 W was supplied. Gases of SF6 and O2 were used. The discharge pressure was 30 Pa. The researchers monitored the AE and VP probe sensor signals using a multichannel digital data recorder.
Monitoring showed the VP probe was very sensitive to change in electrical potential, showing a sharp negative output voltage (Figure ). This indicates that the flux of electron flow from the plasma increased at the moment that the anomalous discharge occurred. The anomalous discharge caused a plasma state where the plasma density and/or electron temperature was higher than at steady state. The AE sensor detected the change in potential just milliseconds after the VP probe — indicating the propagation delay of the AE wave along the chamber wall.
![]() |
| Signal waveform of the view-port probe shows that the indicating signal appears prior to the anomalous discharges. |
Moisture in the chamber caused abnormal discharges to occur ~3 sec apart for 10 min. When the wafer was replaced with another wafer with moisture, the same phenomena occurred. Signals from the particle monitor were coincident with the AE sensor and VP probe signals.
The group determined that, by lowering the voltage applied to the ESC wafer stage, fewer abnormal discharges occurred. Therefore, they developed an electric feedback system that controls the ESC voltage using the foreseeing signal as a trigger. The system consists of an A/D converter to control the ESC voltage and an electronic system that records the discharge signals and analyzes the position of the abnormal discharge points.
The feedback system responds to the foreseeing signal of the VP probe and applies voltage to the ESC. When the ESC voltage control is employed, the anomalous discharge is completely suppressed.
Find more information on yield management.